Differential Pressure Flowmeters

Differential pressure (DP) flowmeters for stable flow measurement in liquids, gases and steam. Heavy-duty instruments that withstand pressures up to 40 MPa and temperatures from -40 °C to 150 °C, ideal for boiler steam, refrigeration circuits and chemical processes with or without suspended solids.

About this category

Differential Pressure (DP) Flowmeters

Differential pressure (DP) flowmeters are classic, extremely robust instruments within industrial instrumentation. They are designed to measure the flow of liquids (both conductive and non-conductive), gases and steam with high stability, standing out for their ability to operate under extreme mechanical pressures and temperatures.


Operating Principle

This technology determines flow from the pressure difference generated when the fluid passes through a restriction in the pipe (such as an orifice plate, a valve or a Venturi tube).

Based on Bernoulli's principle, as the fluid velocity increases at the restriction, the pressure decreases. By accurately measuring the pressure difference ($\Delta P$) between the upstream point ($P_1$) and the downstream point ($P_2$), the actual volumetric flow is calculated through the basic mathematical relationship:

$$Q = \sqrt{\frac{\Delta P}{\rho}}$$

Where:

  • $Q$: Flow rate
  • $\Delta P$: Pressure difference ($P_1 - P_2$)
  • $\rho$: Fluid density

Key Advantages of Differential Pressure (DP) Measurement

  • Fluid Versatility: Suitable for measuring both conductive and non-conductive liquids, gases and steam.
  • High-Pressure Support: The preferred engineering choice for processes with critical rated pressures of up to 40 MPa.
  • High Stability and Repeatability: Delivers highly repeatable, stable measurement behavior in continuous flow regimes.
  • Wear Resistance: Depending on the primary element configuration, certain models can handle fluids with solids or suspended particles without mechanical damage.

Technical Specifications and Process Conditions

Measuring Ranges and Performance

  • Pipe Diameters: Standard range from DN25 to DN500 (with custom design options up to DN1200 or larger depending on the project).
  • System Accuracy: Maintains a typical accuracy range of $\pm1%$ to $\pm3%$ of reading (subject to the specific primary element model and installation conditions).
  • Flow Range: From $0.1 \text{ m}^3\text{/h}$ to thousands of cubic meters per hour.

Operating Limits and Pressure Losses

  • Fluid Temperature: Excellent thermal performance from $-40^\circ\text{C}$ to $150^\circ\text{C}$.
  • Operating Pressure: Structural strength of up to 40 MPa in high-end models.
  • Permanent Pressure Loss: Its optimized geometric design generally keeps the pressure loss below 0.3 MPa.

Materials and Industrial Connectivity

Available Materials

  • Wetted Components: Components made as standard of SUS316 Stainless Steel to ensure a long service life against corrosion.
  • Process Connections: Flanged connection per ANSI, JIS or DIN standards (with custom options for specific projects).
  • Installation Flexibility: Supports local or remote mounting configurations to protect the electronics according to the plant's physical environment.

Signal Integration (PLC / SCADA)

Equipped with smart transmitters that facilitate automation:

  • 4-20 mA analog output for continuous variable control.
  • Pulse or Frequency output for totalization and fast monitoring.
  • RS-485 / Modbus and HART industrial communication protocols.
  • Environmental Protection: IP67 / NEMA 4X hermetic sealing with certified options for operation in Hazardous Areas (Ex).

Typical Industrial Applications

  1. Thermal Systems and Boilers: Continuous measurement of steam, gas or air in boilers and turbines for optimal operational control and energy efficiency.
  2. Complex Fluid Handling: Monitoring and measurement of slurries, dense mixtures and sludge circulation in internal plant movements.
  3. Refrigeration Systems: Flow control in closed heat-exchange circuits and cooling towers to ensure overall efficiency.
  4. Water Networks and Infrastructure: Flow control in process water lines, industrial water and effluent conveyance.
  5. Continuous Chemical Processes: Flow instrumentation in reaction lines to ensure stability, efficiency and consistent production quality.
  6. Reagent Transfer: Accurate measurement in transfer lines for industrial reagents and resins (depending on the technical configuration).

There are no products available in this category yet.

View the full catalog