Level Measurement

Subcategories

Industrial Level Switches and Point Level Sensors

# Industrial Level Switches and Point Level Sensors

**Level switches** (or point level switches) are essential safety and control devices in any industrial setup. Unlike continuous transmitters, these devices are designed specifically to detect the presence or absence of material at a predetermined critical point in the line or tank. On reaching that limit, they switch a discrete (ON/OFF) signal that immediately triggers safety alarms, emergency stops or automated fill and drain cycles.

---

## Operating Principle and Technologies

To offer maximum operational versatility across the different physical properties of the media, this family of instruments can be configured under several detection principles:

* **Mechanical and Float Principles:** Ideal for direct, reliable detection in clean or utility liquids.
* **Vibrating Principles (Forks / Tuning Forks):** Highly effective in both liquids and bulk solids, offering total immunity to foam, turbulence or ambient dust buildup.
* **Optical Principles:** Designed for ultra-fast switching response, commonly applied in selective phase detection or critical containment systems.

Its advanced engineering allows the instrument to ignore critical factors such as residual product buildup on the sensor, dense dust clouds in the surrounding environment or thick layers of surface foam.

---

## Technical Specifications and Process Limits

### Mechanical and Detection Capabilities
* **Measurement Type:** Fixed point detection (configurable as a high-level alarm, low-level alarm or presence sensor).
* **Reach and Length:** Models with customizable insertion length or mechanical reach of **up to 20 meters or more** depending on the technology design.
* **Density Sensitivity:** Ability to detect media with a minimum density from **0.5 g/cm³**.

### Operating Conditions
* **Process Temperature:** Wide working temperature range from **$-40^\circ\text{C}$ to $200^\circ\text{C}$**.
* **Process Pressure:** Designed to withstand from **absolute vacuum up to 40 bar** of hydromechanical pressure.

### Electrical Data and Integration
* **Discrete Control Outputs:** Configurations available with **dry contact (relay)** for high power or solid-state **transistor (NPN/PNP)** outputs for fast integration.
* **Power Supply:** Instrument families adapted for **10-30 Vdc** ranges in low-voltage control loops, or **100-240 Vac** for general power networks.
* **Field Indication:** Modules fitted with high-brightness local LED indicators to verify switching status directly in the plant.

---

## Construction Materials and Protection

### Available Materials
* **Wetted Areas:** Standard construction in highly chemical-resistant stainless steels (**SUS304, SUS316 and SUS316L**).
* **Aggressive Media:** A range of advanced engineering polymers and special protective coatings to withstand corrosive agents or highly adhesive fluids.

### Environmental Certifications
* **Ingress Protection:** Enclosures certified to **IP65, IP66, IP67 and IP68** protection ratings.
* **External Mechanical Resistance:** Enclosures per **NEMA 4 and NEMA 4X** standards against water jets and outdoor corrosion.
* **Intrinsic Safety:** Options with **Ex d** explosion-proof and **Ex ia** intrinsic safety certifications for operation in hazardous areas with a risk of flammable gases or dust.

---

## Typical Industrial Applications

1. **Critical Safety Alarms:** Point monitoring of maximum and minimum levels in storage tanks, recirculation tanks and sumps to prevent accidental overflows.
2. **Hydraulic Pump Protection:** Digital low-level interlock to actively prevent dry-running and cavitation in process pumps and impellers.
3. **Hopper and Solids Silo Control:** Automated management of filling and discharge of industrial powders, grains and granular materials of varying density.
4. **Loading and Transfer Lines:** Detection of actual material presence in discharge pipes or pneumatic or hydraulic conveying lines.
5. **Leak Detection:** Safety sensing in drip trays, chemical spill containment bunds and double-wall systems in critical fuel tanks.

Magnetostrictive Level Transmitter (Float)

# Magnetostrictive Level Transmitter (Float)

The **magnetostrictive level transmitter** represents the highest-precision, highest-stability technology for continuous level and interface measurement in storage tanks and industrial processes. Based on an advanced physical operating principle, this instrument determines with absolute accuracy the position of a magnetic float on a vertical guide, providing repeatable, drift-free readings.

---

## Operating Principle

This instrument uses the magnetostriction phenomenon to calculate the exact position of the fluid:

1. **Electrical Pulse:** The transmitter generates and sends an electrical pulse that travels along a highly sensitive sensing wire inside the instrument's guide.
2. **Magnetic Interaction:** On meeting the magnetic field of the float (which moves freely along the guide following the liquid level), a mechanical deformation occurs in the wire, generating a torsional wave.
3. **Return Time Calculation:** The electronic module in the head measures with extreme precision the time this return wave takes to reach the sensor, converting this time variable into the absolute level position of the fluid.

This technology can also be configured with a dual float to simultaneously determine the interface level between two liquids of different density in the same tank.

---

## Key Advantages of Magnetostrictive Measurement

* **Extreme Accuracy and Repeatability:** Based on measuring the return time of a physical signal, it delivers absolute position values of very high fidelity, with no drift over time.
* **Reliable Interface Measurement:** Allows simultaneous quantification of the level of two immiscible liquids (such as water and fuels).
* **Robust Modular Structure:** Available in stainless steel and with advanced engineering plastic options to resist highly corrosive fluids.
* **Low Maintenance:** Its simple mechanical design with a sliding magnetic float ensures long-lasting operation, minimizing maintenance operating costs.

---

## Technical Specifications and Process Conditions

### Measuring Ranges and Performance
* **Measuring Range (Probe Height):** Sensor length available from **50 mm to 5,500 mm**.
* **Output Signal:** Standard **2-wire 4-20 mA** output.
* **Available Communications:** **HART** communication protocol and/or **RS-485** digital interface.
* **Power Supply:** Operating range of **12 to 30 VDC**.

### Operating and Environmental Limits
* **Process Pressure:** Withstands operating pressures of up to **30 bar**.
* **Process Temperature:** Designed to tolerate wide ranges from **$-40^\circ\text{C}$ to $200^\circ\text{C}$**.
* **Ambient Temperature:** Resistant to extreme conditions from **$-40^\circ\text{C}$ to $85^\circ\text{C}$**.
* **Protection Ratings:** Head protection of **IP65 to IP67**, with a probe designed to tolerate extreme hygienic conditions up to **IP69K**.
* **Safety Certifications:** Configurable options for installation in **Hazardous Areas (Ex)**.

---

## Available Materials (Wetted Parts)

To ensure the instrument's durability against various degrees of corrosion or sanitary requirements, the following material configurations are available:

* **High-Strength Metal:** Industrial-grade **SUS304 and SUS316** Stainless Steel.
* **Corrosion-Resistant Engineering Plastic Options:** Linings and guides made of **PVC / HT-PVC, PFA / Teflon and PP / PTFE**, optimal for aggressive chemical applications.

---

## Typical Industrial Applications

1. **Fuel and Oil Tanks:** Precise monitoring of hydrocarbon level, including exact detection of the critical water/oil interface in settling or drain systems.
2. **Dosing and Chemical Tanks:** Reliable level control in preparation tanks storing strong acids, alkalis, reagents or other corrosive chemical solutions.
3. **Process Water and General Services:** Continuous measurement to automate filling, emptying and water balance control in industrial plants.
4. **Water and Effluent Treatment:** Robust instrumentation in tanks, sumps or chambers that require a stable, disturbance-free level signal.
5. **Mounting on External Chambers and By-Pass:** Option to install the sensor on an existing magnetic level indicator or in an external By-Pass chamber to isolate the probe from the direct fluid.

Hydrostatic Piezoresistive Level Transmitter

# Hydrostatic Piezoresistive Level Transmitter

The **piezoresistive level transmitter** is an instrument designed for continuous, reliable level measurement in open tanks, wells, channels and industrial accumulation chambers. Based on the principle of hydrostatic pressure, this submersible instrument delivers a highly stable, robust reading, making it the preferred choice for handling process water, effluents and fluids containing fine solids.

---

## Operating Principle

This instrument determines the fill level by calculating the weight of the fluid column resting on it:

1. **Hydrostatic Pressure:** The sensor directly measures the pressure exerted by the liquid column on a sensitive diaphragm exposed to the medium.
2. **Piezoresistive Effect:** The mechanical deformation of the diaphragm due to pressure is transmitted directly to an internal piezoresistive sensing element, whose electrical resistance varies in proportion to the applied force.
3. **Conversion to Industrial Signal:** The integrated electronic circuit converts this resistance change into a standardized electronic signal directly proportional to the liquid level in the tank.

*Installation technical note:* This measurement principle requires tanks vented to atmosphere or with stable gas pressure. If there is variable back pressure in the tank's vapor space, it must be compensated externally to maintain maximum accuracy.

---

## Key Advantages of the Submersible Hydrostatic Transmitter

* **Deep Measurement:** Ability to measure long vertical water columns in deep wells or mega-tanks.
* **Resistance to Complex Fluids:** Its smooth mechanical design with no moving parts lets it operate effectively with liquids containing diluted sludge or fine suspended solids without clogging.
* **Hermetic Construction:** Offers maximum protection against water ingress, ensuring continuous long-term submerged operation.
* **Direct Installation:** Easy suspended mounting using its own reinforced submersible cable.

---

## Technical Specifications and Process Conditions

### Measuring Ranges and Performance
* **Level Range:** Effective measurement of **0 to 100 meters** of water column (for fluids with Specific Gravity SG = 1).
* **Equivalent Pressure:** Operating scale of **0.1 to 10 bar**.
* **Output Signal:** Standard industrial analog protocol of **2-wire 4-20 mA**.
* **Power Supply:** Flexible input range from **13 to 36 VDC**.
* **Loop Resistance:** Maintains a low impedance of **< 500 Ω**.

### Operating and Environmental Limits
* **Process Temperature:** Withstands thermal conditions from **$-10^\circ\text{C}$ to $150^\circ\text{C}$**.
* **Protection Ratings:** Configured with an external housing with **IP65** protection and a submersible probe with absolute watertight **IP68** sealing.
* **Industrial Safety:** Approved versions available for **Hazardous Areas (Ex)**.

---

## Available Materials

* **Primary Wetted Parts:** Diaphragm and sensor body made of industrial-grade **SUS304 and SUS316** stainless steel.
* **Transmitter Housing:** Robust aluminum alloy.
* **Submersible Connection Cable:** Specially insulated **PVC** cable with configurable lengths of **up to 100 meters**.

---

## Typical Industrial Applications

1. **Industrial and Process Water:** Continuous control and balancing of consumption in discharge lines, recirculation loops and storage by plant area.
2. **Effluent and Wastewater Treatment:** Instrumentation in equalization tanks, clarifiers and sludge wells loaded with fine solids.
3. **Automatic Pump Control:** Level measurement in pump sumps, open channels and recirculation chambers to act as the main process control variable.
4. **Dosing and Reagent Tanks:** Inventory control in preparation, dilution and storage tanks for chemical solutions, additives and utility water compatible with stainless steel.
5. **Diluted Slurries and Grouts:** A robust alternative for measurement in tanks containing low-abrasion suspensions where other technologies suffer interference.
6. **Thickening and Settling Processes:** Monitoring in settling wells and accumulation boxes for automated management of critical alarms and purge operation.
7. **Thermal and Industrial Networks:** Stable measurement in steam condensate tanks, hot water lines and severe thermal recirculations.

Guided Wave Radar (GWR/TDR) Level Transmitter

# Guided Wave Radar (GWR/TDR) Level Transmitter

The **guided wave radar level transmitter** (GWR, also known as TDR) is one of the most stable and accurate continuous measurement technologies on the industrial market. By channeling electromagnetic pulses along a rigid or flexible physical guide, this instrument completely eliminates signal scattering and the false echoes caused by tank obstructions, delivering outstanding performance in environments with extreme turbulence, heavy foam or dense vapors.

---

## Operating Principle

Guided wave technology bases its operation on time-domain reflectometry:

1. **Pulse Emission:** The electronic head emits low-energy microwave pulses that travel, guided along a physical probe (rod or cable), into the tank.
2. **Reflection from Dielectric Change:** When the signal hits the product surface, it detects an abrupt change in the medium's dielectric constant, causing part of the pulse to reflect and return along the same probe to the sensor.
3. **Conversion and Interface Control:** The digital transducer calculates the total round-trip transit time with maximum fidelity and converts it into a continuous level reading. In addition, if the remaining pulse continues down through a light non-conductive phase (such as oil), a second reflection is generated when it hits the heavy conductive phase (such as water), allowing simultaneous interface measurement between two liquids.

---

## Key Advantages of GWR Guided Radar

* **Immunity to Space Disturbances:** Guiding the signal prevents the microwaves from scattering, allowing the instrument to be installed a few centimeters from the tank walls or in complex internal geometries with heating coils, side inlets or mechanical agitators.
* **Process-Independent Performance:** Maintains impeccable accuracy even under dense layers of surface foam, boiling, airborne dust clouds or saturated steam and condensation on the head.
* **Simultaneous Interface Measurement:** An optimal solution for decanters and water/hydrocarbon phase separators.
* **Low Density Impact:** The reading depends solely on the medium's surface dielectric constant, unaffected by variations in the product's density or specific gravity.

---

## Technical Specifications and Process Conditions

### Measurement Capabilities and Ranges
* **Continuous Level Measurement:** Linear coverage scale from **0.5 to 20 meters** in height.
* **Interface Layer Measurement:** Phase detection range of **up to 10 meters** of vertical length.
* **Dynamic Performance:** High resolution and repeatability optimized for critical analog process control loops and operational balances.

### Operating and Mechanical Limits
* **Process Temperature:** Extended thermal tolerance range of **$-40^\circ\text{C}$ to $230^\circ\text{C}$**.
* **Process Pressure:** Designed to operate safely under conditions from **absolute vacuum up to 60 bar**.

### Electrical Connectivity and Integration Data
* **Analog Output:** Standard **4-20 mA** DC current loop for real-time control.
* **Digital Communication:** Advanced industrial **HART** protocols and **RS-485 over Modbus** digital interface.
* **Network Compatibility:** Direct integration into distributed architectures through PLC controllers, DCS systems and SCADA platforms.

---

## Available Materials and Probe Types

To provide maximum adaptability to the different mechanical stresses and chemical compositions of fluids, probes are configured according to each technical requirement:
* **Base Metal Probes:** Rods and cables made of industrial-grade **SUS304 and SUS316** stainless steel.
* **Insulation and Chemical Coatings:** Fully insulated probe options in **PTFE / PFA**, recommended to prevent electrical short circuits in conductive liquids or to resist attack in highly corrosive environments.
* **Structural Geometries:** Variants in **rigid rod** format (for short lengths and agitated tanks) or **flexible cable** (for tall silos or deep tanks).

### Protection Ratings and Certifications
* **Environmental Sealing:** Hermetic housing with **IP67** protection against dust and water ingress.
* **Plant Safety:** Models and families with approvals and versions suitable for installation in **Hazardous Areas** with a latent explosion risk.

---

## Typical Plant Applications

1. **Turbulent and Agitated Tanks:** Continuous level measurement in reactors and process tanks that experience strong mechanical agitation, waves or surface foam formation.
2. **Phase Separators and Decanters:** Accurate interface measurement in hydrocarbon separators, where the separation of layers (light phase / heavy phase) must be controlled precisely.
3. **Tanks with Complex Internal Geometry:** Instrumentation in narrow tanks or those with a high density of internal structural obstacles (such as cooling coils or crossing pipes) where non-guided radars lose stability.
4. **Solution and Slurry Preparation:** Inventory control in storage tanks for reactive mixtures or slurries with suspended fines, avoiding buildup that would obstruct the instrument.
5. **Wet Material Silos and Hoppers:** Robust measurement in powder or granule silos prone to generating dense material clouds or internal condensation.
6. **Clarification and Thickening Circuits:** Stable monitoring in settling boxes and recirculation tanks where the product undergoes dynamic, drastic density changes.

Plumb-Bob Level Transmitter and Indicator

# Plumb-Bob Level Transmitter and Indicator

The **plumb-bob level transmitter and indicator** is a highly robust electromechanical instrument designed specifically for inventory management of bulk solids in tall silos and hoppers. Unlike ultrasonic or radar systems, which often suffer interference in dense atmospheres, this electromechanical technology provides a direct, fully stable physical measurement in environments with heavy airborne dust or sticky materials.

---

## Operating Principle

The instrument operates automatically or on demand through a precision electromechanical cycle:

1. **Plumb-Bob Descent:** The system releases a cable with a calibrated-weight plumb bob that descends vertically from the top of the silo.
2. **Surface Detection:** On touching the surface of the bulk material, the instrument instantly detects the change in tension and the loss of weight on the cable.
3. **Calculation by Revolution Count:** At that moment, the motor stops the descent and begins to retract the cable. The processor calculates the exact level distance from the length of cable paid out, using an ultra-precise count of revolutions and pulses from the internal pulley system.

*Installation technical note:* This measurement principle requires the plumb bob's descent path to be completely free of obstructions, structural beams or direct fill streams.

---

## Key Advantages of the Industrial Plumb-Bob Probe

* **Total Dust Immunity:** Being a mechanical measurement by physical contact, heavy dust clouds during filling have no effect at all on the reading.
* **Independence from Material Properties:** Delivers exact measurements regardless of changes in the solid's density, dielectric constant, moisture or composition.
* **Adaptable Plumb Bobs:** Allows different plumb-bob geometries and weights to be fitted to prevent the sensor from sinking into low-density materials or ultra-fine powders.
* **Ideal for Tall, Narrow Silos:** Avoids false readings and echo losses caused by reflections off the walls of narrow silos.

---

## Technical Specifications and Process Conditions

### Measuring Ranges and Performance
* **Measuring Distance:** Extended coverage of **up to 45 meters**.
* **Upper Blind Zone:** A technical safety clearance of **0.6 meters** must be allowed for.
* **Pulse Resolution:** Configurable pulse outputs at **10 mm/pulse and 100 mm/pulse**.

### Electrical Data and Connectivity
* **Analog Output:** Standard **4-20 mA** DC current signal.
* **Digital Communication:** Native **RS-485 over Modbus protocol**.
* **Control Outputs:** Equipped with 3 relay output channels rated **3 A / 250 Vac** for alarms or interlocks.
* **Power Supply:** Universal range of **88 to 264 Vac (50/60 Hz)**.

### Operating and Environmental Limits
* **Operating Temperature:** Designed for continuous operation from **$-35^\circ\text{C}$ to $105^\circ\text{C}$**.
* **Protection Ratings:** Hermetic enclosure rated **IP66** and **NEMA 4X**.
* **Hazardous Area Safety:** Versions with **Ex d** explosion-proof certification for flammable environments or combustible dust.

---

## Available Materials

* **Main Body and Housing:** High-mechanical-strength die-cast aluminum alloy.
* **Sensing Elements:** A variety of metal plumb bobs with specific geometries and weights adaptable to the friction and support characteristics of the bulk solid.

---

## Typical Industrial Applications

1. **Lime and Cement Silos:** Exact stock and inventory control in bulk storage silos for cement, quicklime, fly ash and abrasive industrial powders.
2. **Dry Reagents and Additives:** Level measurement in storage tanks and hoppers for powdered reagents used in dosing processes.
3. **Granular Materials and Pellets:** Robust monitoring in storage silos for plastic pellets, resins, rubber granules, industrial salts and fertilizers.
4. **Coal and Coke Storage:** Volume management in silos storing crushed coal, petroleum coke and other powdery materials with a high risk of explosive dust atmospheres.
5. **Wood Chips and Biomass:** Level measurement in feed silos for biomass boilers, sawdust and wood chips, where surfaces are highly irregular.

RF Admittance (Capacitive) Level Transmitters

# RF Admittance (Capacitive) Level Transmitters

**RF admittance** (radio frequency) or capacitive **level transmitters** are high-technology instruments designed for continuous level measurement in a wide variety of industrial applications. This technology stands out for its versatility in handling both liquids and bulk solids (powders and granulates), and excels in demanding environments thanks to advanced functions that ignore mechanical buildup of material on the sensing element.

---

## Operating Principle

The system determines the tank level by measuring electrical variables proportional to the fill volume:

1. **Dielectric Variation:** The instrument constantly detects the change in capacitance or electrical admittance generated between the installed sensing probe and the metal tank wall (or a secondary reference electrode).
2. **Material Effect:** As the fluid or solid rises or falls, it displaces air and acts as a variable dielectric medium around the rod or cable, changing the picofarads (pF) recorded.
3. **Conversion and Coating Rejection:** The electronic circuit converts the electrical range (which varies from tens to thousands of pF) into a linear level signal. Advanced models incorporate active shield technology (coating rejection / guard) to suppress bridging or coating effects from sticky materials, eliminating false readings caused by buildup.

*Technical recommendation:* In processes handling water-based conductive liquids, a probe with polymer insulation must be used to prevent short circuits from wetting and to reduce false indications caused by residual wet films.

---

## Key Advantages of RF Admittance

* **Immunity to Buildup:** The coating rejection function allows accurate measurement of wet materials or materials that tend to stick to the probe.
* **Media Versatility:** Suitable for measuring conductive and non-conductive products, including fine powders with airborne dust.
* **High-Temperature Construction:** Ceramic insulators available to withstand thermal shock and instrumentation in severe processes.
* **No Moving Parts:** Its solid-state design minimizes predictive maintenance requirements.

---

## Technical Specifications and Process Conditions

### Measuring Ranges and Probe Configuration
* **Rod-Type Probes:** Reference physical length of around **1.2 to 1.5 meters**.
* **Suspended Cable Probes:** Typical measuring length of **up to 15 meters**, with engineering configurations able to reach **up to 50 meters** of vertical range.
* **Transmitter Electrical Range:** Reading capacity in the order of tens to thousands of pF (picofarads), adapting to the model and the product being measured.

### Operating and Environmental Limits
* **Operating Temperature:** From cryogenic or standard ranges of **$-40^\circ\text{C}$ to $85^\circ\text{C}$** in base versions, extending **up to $200^\circ\text{C}$** in high-temperature models.
* **Process Pressure:** Mechanical strength of **32 to 40 atm** depending on connection and body type.
* **Industrial Output and Communication:** Standard **4-20 mA (2-wire)** current loop with digital integration option via **HART** protocol.
* **Sealing and Hygiene Rating:** Designed to **IP65** protection standards, with variants certified **EX (Explosion Proof)**.

---

## Available Materials

* **Sensing Element:** Probe core made of high-specification stainless steel.
* **Insulators and Chemical Coatings:** Protective sleeves in **PFA, Kynar (PVDF)** and advanced engineering polymers for chemical compatibility and insulation in conductive liquids.
* **Superior Thermal Insulation:** **Ceramic** connectors and barriers for high-temperature processes.

---

## Typical Industrial Applications

1. **Silos and Hoppers with Bulk Solids:** Continuous inventory monitoring in powder and granulate silos with dense dusty atmospheres that require a robust contact sensor.
2. **Wet or Sticky Materials:** Accurate measurement in product lines with high probe adhesion using electronics with coating rejection.
3. **Metal and Non-Conductive Tanks:** Direct instrumentation using the tank walls as reference, or installation with a reference electrode in plastic or non-conductive vessels.
4. **Processes with Product Changeover:** Measurement in multi-product tanks that allow local or remote recalibration according to the change in the material's dielectric constant.
5. **Water-Based Conductive Liquids:** Level control in aqueous solutions using insulated probes to eliminate the error from a wet film on the sensor surface.

FMCW Radar Level Transmitters

# FMCW Radar Level Transmitters: Advanced Non-Contact Measurement

**FMCW (Frequency Modulated Continuous Wave) radar level transmitters** are the most advanced and reliable engineering solution for continuous level measurement in large tanks and silos. Operating in a completely non-intrusive way (with no direct contact with the medium), this type of radar eliminates at the root failures caused by mechanical wear, product buildup or chemical attack, guaranteeing readings with maximum long-term stability.

---

## Operating Principle

FMCW technology bases its accuracy on continuous modulation of the signal:

1. **Microwave Emission:** The instrument continuously emits a microwave signal toward the product surface. This signal is distinctive in that its frequency is constantly varied, or modulated, over time.
2. **Signal Reflection:** The wave travels through the free space of the tank, strikes the surface of the material (liquid or solid) and bounces back to the sensor.
3. **Calculation by Frequency Shift:** The receiver module processes the returned echo and measures with extreme precision the instantaneous frequency difference between the signal being emitted at that microsecond and the signal just received. From this differential value, the transmitter derives the exact distance and determines the actual fluid level.

---

## Key Advantages of Industrial FMCW Radar

* **Environment-Immune Performance:** Maintains absolute analytical accuracy even in the presence of dense airborne dust clouds, persistent vapors, severe condensation on the antenna or aggressive process atmospheres.
* **Independence from Fluid Properties:** Effectively measures both conductive and non-conductive liquids, as well as granular solids, fine powders and pellets.
* **Reading on Irregular Surfaces:** Advanced algorithms able to average and stabilize the measurement on solid materials with sloped angles of repose or on highly turbulent liquid surfaces.
* **Zero Mechanical Maintenance Costs:** With no submerged moving parts, plant shutdowns for sensor cleaning or calibration are practically nil.

---

## Technical Specifications and Process Conditions

### Measuring Ranges and Performance
* **Continuous Measuring Range:** Vertical scale coverage from **0.5 to 70 meters** in height.
* **Volume Capacity:** Mathematical stability optimized for operational control in silos and bulk storage tanks.

### Operating Limits and Critical Parameters
* **Process Temperature:** Designed to withstand demanding thermal ranges from **$-40^\circ\text{C}$ to $250^\circ\text{C}$**.
* **Process Pressure:** Structural strength suited to operate from **absolute vacuum up to 40 bar**.

### Connectivity and Electrical Integration Data
* **Continuous Analog Output:** Traditional **4-20 mA** current loop for real-time control.
* **Digital Communication:** Native connectivity through **HART** and **RS-485 over Modbus** industrial automation protocols.
* **Network Integration:** Full compatibility for direct incorporation into distributed PLC, DCS and SCADA architectures.

---

## Available Materials and Antenna Types

To adapt precisely to the geometry and chemical aggressiveness of each application, the radar is available in different structural configurations:
* **Antenna Base Material:** Standard construction in high-purity stainless steel.
* **Chemical-Safety Coatings:** Antennas fully encapsulated or coated in **PTFE / PFA** to operate safely in highly corrosive environments or with concentrated acids.
* **Configurable Antenna Geometries:** Models available with **lens, horn or planar** designs optimized according to the beam angle and the presence of structural obstacles in the tank.

### Protection Ratings and Certifications
* **Environmental Sealing:** Hermetic enclosures certified to **IP67 and IP68** protection ratings against flooding or severe weather.
* **Plant Safety:** Versions specially approved and certified for use in **Hazardous Areas** with a latent explosion hazard.

---

## Typical Industrial Applications

1. **Large-Volume Tanks and Stock:** Continuous inventory measurement in mega storage tanks where interrupting operation or installing invasive mechanical elements is not permitted.
2. **Tall Solids Silos:** Level control in tall mining, cement or agricultural silos containing powders, grains or pellets with conical, irregular surfaces.
3. **Aggressive Chemical Atmospheres:** Level instrumentation in reagent tanks with heavy corrosive gas emissions, high temperatures or a risk of material buildup on the tank walls.
4. **Processes Generating Dust or Vapor:** Reliable measurement in transfer hoppers with heavy fine-dust suspension or in reactors with strong evaporation and condensation.
5. **Low-Maintenance Fuel Tanks:** Large hydrocarbon storage and transfer terminals where safety and zero field maintenance are the priority.
6. **Portable or Limited-Access Measurement:** Installation in closed tanks or confined areas where physical access for technical maintenance is restricted, hazardous or undesirable.

Ultrasonic Level Transmitters

# Ultrasonic Level Transmitters: Efficient Non-Contact Measurement

**Ultrasonic level transmitters** are a classic, cost-effective and highly reliable solution for automation and continuous inventory control in industrial tanks and wells. Operating in a fully non-intrusive way using sound waves, these instruments eliminate the risk of mechanical blockages or degradation from chemical contact, drastically simplifying field maintenance tasks.

---

## Operating Principle

The ultrasonic transmitter bases its accuracy on the propagation and reflection of acoustic waves in the free space of the tank:

1. **Acoustic Emission:** The transducer integrated in the instrument head periodically emits bursts of ultrasonic waves aimed vertically at the material surface.
2. **Echo Reflection:** The acoustic signal travels through the air, strikes the surface of the liquid or granular solid and generates an echo that returns toward the transducer.
3. **Distance Calculation:** The instrument's electronics accurately calculate the total transit time elapsed between emission and reception of the wave to compute the distance and derive the actual fluid level.

To ensure stable readings under dynamic environmental conditions, the module incorporates advanced false-echo filtering algorithms and an automatic temperature compensation sensor.

---

## Key Advantages of Ultrasonic Measurement

* **Fast, Clean Installation:** Its top-mounted threaded fitting allows very fast commissioning with no need to empty or mechanically work on the bottom of the tank.
* **Low Maintenance:** With no submerged moving parts, dirt buildup and mechanical wear are nil, reducing technical downtime.
* **Adaptable to Media with Solids:** Excellent performance in effluents and diluted hydrocarbons containing fine suspended solids, where other contacting technologies fail due to clogging.
* **Use in Humid Spaces:** The hermetically sealed design handles saturated humidity and ambient condensation exceptionally well.

---

## Technical Specifications and Process Conditions

### Measuring Ranges and Performance
* **Continuous Measuring Range:** Effective linear coverage from **0.5 to 11 meters** in height.
* **Upper Dead Zone:** Requires a clearance of **0.3 to 0.45 meters** measured from the transducer face.
* **Operational Performance:** High technical repeatability optimized for continuous monitoring loops and automatic pump control.

### Process Operating Limits
* **Process Temperature:** Designed to operate stably between **$-30^\circ\text{C}$ and $70^\circ\text{C}$**.
* **Process Pressure:** Withstands from slight vacuum of **-0.25 bar up to 3 bar** of hydromechanical pressure.
* **Vessel Types:** Suited to open tanks, channels, underground chambers or closed tanks with proper atmospheric venting.

### Signals and Integration (PLC / SCADA)
* **Analog Output:** Standard industrial **2-wire 4-20 mA** DC current loop.
* **Digital Communication:** Native **HART** protocol for configuration and advanced diagnostics.
* **Discrete Outputs:** Equipped with **independent relay** contacts configurable for critical high and low level alarms.

---

## Materials and Process Connection

* **Transducer Material:** Made of high-chemical-resistance **PVDF** to ensure durability against aggressive fluids or industrial effluents.
* **Mechanical Coupling:** Standard **2-inch (2") threaded connection in BSPT or NPT configurations**.
* **External Sealing Rating:** Outer enclosure certified to **IP67** protection against dust and water ingress.
* **Industrial Safety:** Approved versions available for safe installation in **Hazardous Areas**.

---

## Typical Plant Applications

1. **Wet Wells and Sumps:** Continuous level measurement in pump chambers, intake wells and industrial sumps to automate pump start-up and manage flood alarms.
2. **Industrial Water Tanks:** Storage control in process water tanks, closed recirculation circuits and water consumption balances by plant area.
3. **Effluent Treatment Plants:** Robust instrumentation in wastewater tanks, industrial effluents and clarified water tanks that require stable control signals.
4. **Slurries and Diluted Solutions:** Level control in preparation tanks for low-density mixtures and chemical additives, provided the surface remains measurable.
5. **Open Channels and Weirs:** Accurate water-surface level measurement for the mathematical calculation of flow in weirs or fluid distribution channels.
6. **Granular Material Hoppers:** Monitoring in small hoppers or silos handling pellets or bulk solids with low or controllable airborne dust generation.

Industrial Capacitive Level Transmitters and Indicators

# Industrial Capacitive Level Transmitters and Indicators

**Capacitive level transmitters** are a high-fidelity, rugged technology for continuous monitoring of inventories and industrial processes. Thanks to their solid-state physical principle, these instruments provide stable measurements in both conductive and non-conductive liquids and in bulk solids (powders and granules), standing out for their total immunity to dense airborne dust clouds and to turbulence generated during filling.

---

## Operating Principle

The system continuously determines the volume or height of the medium based on the electrical properties of the tank:

1. **Capacitance Circuit:** The probe acts as a primary electrode, while the metal tank wall (or an auxiliary grounding rod) serves as the electrical reference point.
2. **Dielectric Change:** As the product (liquid or solid) rises and interacts with the probe, it displaces air and directly alters the overall dielectric constant of the surrounding medium.
3. **Linear Conversion:** The high-resolution electronic module captures this capacitance variation and instantly converts it into an analog signal proportional to the actual material level.

---

## Key Advantages of Capacitive Technology

* **Stability in Dusty Environments:** The mechanical and electrical reading remains completely unaffected by airborne dust, overcoming the common limitations of optical or ultrasonic sensors.
* **Wide Temperature Range:** Advanced cells and mechanical seals available to tolerate cryogenic and extreme-heat environments.
* **Adaptable Sensitivity:** Smart electronics with configurable sensitivity calibration to match the probe geometry and material properties precisely.
* **Wear-Free Design:** With no mechanical moving parts, the probe offers a long service life with minimal maintenance demands.

---

## Technical Specifications and Process Conditions

### Measuring Range and Adjustment
* **Maximum Probe Length:** Extended-length probe designs covering **up to 4 meters** in continuous measurement.
* **Electrical Resolution:** High sensitivity adjustable to the specific dielectric constants of the process material.

### Operating and Environmental Limits
* **Maximum Operating Pressure:** Hydromechanical structural strength of up to **980 kPa**.
* **Process Temperature (Standard):** Continuous working range from **$-25^\circ\text{C}$ to $+80^\circ\text{C}$**.
* **Process Temperature (Special Versions):** High-thermal-engineering designs to withstand from **$-200^\circ\text{C}$ to $+500^\circ\text{C}$**.

### Connectivity and Electrical Integration
* **Output Signal:** Standard industrial analog loop of **4-20 mA DC** (able to handle a maximum load of 500 Ω depending on the model).
* **Flexible Power Supply:** Versions with classic voltage ranges of **105/210 VAC** and low-voltage options of **24 VDC**.
* **Protection Ratings:** Hermetic outer enclosure certified to **IP65 and IP67** standards.
* **Intrinsic Safety:** Approvals available with **Ex** certification for atmospheres with a potential explosion risk.

---

## Available Construction Materials

To ensure absolute durability against corrosive fluids or highly abrasive solids, the sensor is configured with advanced materials:
* **Metals and Alloys:** Premium-grade Stainless Steel (**SUS304 and SUS316**), plus technical options such as C3604, AC4B and special metals on request.
* **Insulation and Polymers:** High-purity **PTFE (Teflon)** and **Polyacetal** coatings.
* **Thermal Barriers:** Sight glasses or structural components in **Glass (Pyrex)** with high thermal shock resistance.

---

## Typical Industrial Applications

1. **Fine Powder Silos:** Monitoring and critical level alarms in large silos storing soda ash, cement, quicklime and pulverized coal.
2. **Granular Hopper Control:** Stock management in storage cells and feed hoppers containing plastic granules, grains, minerals or metal powders.
3. **Hydraulic and Industrial Monitoring:** Accurate control in industrial water tanks, process water lines and networks that operate directly with seawater.
4. **Wastewater Treatment:** Permanent instrumentation in effluent plants, wastewater pits and primary environmental treatment tanks.
5. **Sludge and Dense Mixtures:** Measurement in preparation and storage tanks for slurries or suspensions loaded with a high concentration of suspended solids.
6. **Common Chemical Storage:** Safe inventory control in plant chemical solution tanks, such as caustic soda and sulfuric acid.
7. **Viscous Fluids and Oils:** Reliable reading in tanks of edible lubricating oils, heavy fuel oils and high-viscosity fluids.
8. **Mineral Suspensions:** Continuous control in agitated tanks of heavy slurries, such as calcium carbonate in suspension and other industrial mineral loads.

Float-Type and By-Pass Level Transmitters and Indicators

# Float-Type (By-Pass) Level Transmitters and Indicators

**Float-type level transmitters and indicators** (including external-chamber By-Pass systems) are instruments designed to provide a highly reliable visual and electronic measurement of liquid level in industrial tanks. Their robust construction and mechanical-magnetic operating principle make them the standard choice for applications that require a high-visibility local reading without depending on electrical power, together with automated signal transmission to the control room.

---

## Operating Principle

These instruments base their operation on the principle of buoyancy and magnetic coupling:

1. **Coupled Movement:** A float or displacer containing an internal magnet moves vertically, following the variations in liquid level in the tank exactly.
2. **External By-Pass Chamber:** The tank level is replicated identically in an external chamber connected to the process at the top and bottom.
3. **Local Visual Indication:** The float's magnetic field acts directly on a strip of two-color magnetic flags on the outside of the chamber, flipping them to show the actual level in real time without requiring electrical power.
4. **Signal Transmission:** The same magnet movement can be picked up externally by a transmitter to convert the reading into a continuous electronic signal (4-20 mA) or to trigger high or low level alarm switches.

---

## Key Advantages of the Float Level System

* **Local Reading Reliability:** A permanent visual indication that is not interrupted by power outages in the plant.
* **Process Separation:** The transmission electronics and alarm switches are installed externally to the By-Pass chamber, completely isolated from the process fluid, which makes maintenance easier without stopping operation.
* **Interface Measurement:** Specific calibration capability to measure the separation or interface between two liquids with different specific gravity.
* **Resistance to Extreme Conditions:** Ideal technology to operate in severe cryogenic or thermal temperature ranges, as well as in high-pressure or vacuum applications.

---

## Technical Specifications and Process Conditions

### Measuring Ranges and Performance
* **By-Pass Chamber Length:** Manufactured from **150 mm to 5,800 mm**.
* **Continuous Measurement (Transmitter):** Electronic reading ranges from **0.15 m to 5.8 m**.
* **Displacer Measurement (Torque Tube):** Typical designs from **0-300 mm to 0-2,000 mm**.
* **Fluid Specific Gravity:** Level operating range from **0.1 to 1.6**.

### Mechanical Operating Limits
* **Process Temperature:** Wide thermal span from **$-196^\circ\text{C}$ (cryogenic) to $450^\circ\text{C}$**.
* **Operating Pressure:** From **absolute vacuum up to 400 bar**.
* **Tank Compatibility:** Suitable for open atmospheric tanks and pressurized vessels.

---

## Available Materials and Connectivity

### Construction Materials
* **Measuring Chamber and Wetted Parts:** High-structural-strength **SUS304 and SUS316** Stainless Steel.
* **Thermoplastic Options:** Process chambers in **Polypropylene (PP) and PVDF** for high compatibility with corrosive or acidic fluids.
* **Accessories and Housings:** Cast aluminum or industrial-grade polymers.

### Signals and System Integration (PLC / SCADA)
* **Visual Indication:** Local magnetic flag indicator that requires no power.
* **Continuous Analog Output:** Standard **4-20 mA** current loop for real-time monitoring and control.
* **Level Switches:** SPDT dry-contact alarms configurable for high and low level limits.
* **Environmental Protection Rating:** Standard **IP65 / IP67** sealing with certified options for safe installation in Hazardous Areas (Ex).

---

## Typical Industrial Applications

1. **Local Indication on Process Tanks:** Robust visual reading through By-Pass chambers on main storage tanks and process surge tanks.
2. **Pump Protection and Overflow Prevention:** Configuration of critical dry-run or overfill alarms using integrated switches.
3. **Water and Effluent Treatment:** Measurement in treated water tanks, process water, industrial effluents and general services.
4. **Fuel Storage Tanks:** Level control and indication in hydrocarbon, solvent and industrial oil tanks.
5. **Chemical Processes with Acids and Bases:** Instrumentation with plastic chambers in storage tanks for aggressive reagents and corrosive solutions.