Float-Type and By-Pass Level Transmitters and Indicators

Float-type level transmitters and indicators and By-Pass systems for continuous measurement and control of liquids in open or pressurized tanks. Mechanically robust instruments that withstand temperatures from -196 °C to 450 °C and pressures from vacuum up to 400 bar, ideal for chemical processes, water treatment and fuels.

About this category

Float-Type (By-Pass) Level Transmitters and Indicators

Float-type level transmitters and indicators (including external-chamber By-Pass systems) are instruments designed to provide a highly reliable visual and electronic measurement of liquid level in industrial tanks. Their robust construction and mechanical-magnetic operating principle make them the standard choice for applications that require a high-visibility local reading without depending on electrical power, together with automated signal transmission to the control room.


Operating Principle

These instruments base their operation on the principle of buoyancy and magnetic coupling:

  1. Coupled Movement: A float or displacer containing an internal magnet moves vertically, following the variations in liquid level in the tank exactly.
  2. External By-Pass Chamber: The tank level is replicated identically in an external chamber connected to the process at the top and bottom.
  3. Local Visual Indication: The float's magnetic field acts directly on a strip of two-color magnetic flags on the outside of the chamber, flipping them to show the actual level in real time without requiring electrical power.
  4. Signal Transmission: The same magnet movement can be picked up externally by a transmitter to convert the reading into a continuous electronic signal (4-20 mA) or to trigger high or low level alarm switches.

Key Advantages of the Float Level System

  • Local Reading Reliability: A permanent visual indication that is not interrupted by power outages in the plant.
  • Process Separation: The transmission electronics and alarm switches are installed externally to the By-Pass chamber, completely isolated from the process fluid, which makes maintenance easier without stopping operation.
  • Interface Measurement: Specific calibration capability to measure the separation or interface between two liquids with different specific gravity.
  • Resistance to Extreme Conditions: Ideal technology to operate in severe cryogenic or thermal temperature ranges, as well as in high-pressure or vacuum applications.

Technical Specifications and Process Conditions

Measuring Ranges and Performance

  • By-Pass Chamber Length: Manufactured from 150 mm to 5,800 mm.
  • Continuous Measurement (Transmitter): Electronic reading ranges from 0.15 m to 5.8 m.
  • Displacer Measurement (Torque Tube): Typical designs from 0-300 mm to 0-2,000 mm.
  • Fluid Specific Gravity: Level operating range from 0.1 to 1.6.

Mechanical Operating Limits

  • Process Temperature: Wide thermal span from $-196^\circ\text{C}$ (cryogenic) to $450^\circ\text{C}$.
  • Operating Pressure: From absolute vacuum up to 400 bar.
  • Tank Compatibility: Suitable for open atmospheric tanks and pressurized vessels.

Available Materials and Connectivity

Construction Materials

  • Measuring Chamber and Wetted Parts: High-structural-strength SUS304 and SUS316 Stainless Steel.
  • Thermoplastic Options: Process chambers in Polypropylene (PP) and PVDF for high compatibility with corrosive or acidic fluids.
  • Accessories and Housings: Cast aluminum or industrial-grade polymers.

Signals and System Integration (PLC / SCADA)

  • Visual Indication: Local magnetic flag indicator that requires no power.
  • Continuous Analog Output: Standard 4-20 mA current loop for real-time monitoring and control.
  • Level Switches: SPDT dry-contact alarms configurable for high and low level limits.
  • Environmental Protection Rating: Standard IP65 / IP67 sealing with certified options for safe installation in Hazardous Areas (Ex).

Typical Industrial Applications

  1. Local Indication on Process Tanks: Robust visual reading through By-Pass chambers on main storage tanks and process surge tanks.
  2. Pump Protection and Overflow Prevention: Configuration of critical dry-run or overfill alarms using integrated switches.
  3. Water and Effluent Treatment: Measurement in treated water tanks, process water, industrial effluents and general services.
  4. Fuel Storage Tanks: Level control and indication in hydrocarbon, solvent and industrial oil tanks.
  5. Chemical Processes with Acids and Bases: Instrumentation with plastic chambers in storage tanks for aggressive reagents and corrosive solutions.

There are no products available in this category yet.