Industrial Flowmeters and Flow Meters

Specialized catalog of flowmeters, flow meters and flow switches for industrial process control. Advanced technology solutions for accurate measurement of liquids, gases, steam and complex fluids in pipes, ensuring efficiency and operational continuity.

Subcategories

Coriolis Flowmeters

# Coriolis Flowmeters: High-Precision Mass Flow and Density Measurement

**Coriolis flowmeters** represent the leading-edge technology for direct, simultaneous measurement of **mass flow, density and temperature**. Designed to deliver exceptional process control, these instruments eliminate the need for external compensation, providing reliable readings even under the most demanding operating conditions.

---

## Operating Principle

This system uses **internal vibrating tubes** driven by an electromagnetic mechanism. As the fluid flows through the sensor, the Coriolis force produces a mechanical twist, causing a **phase shift or deformation** in the tubes' vibration.

* The **phase shift** between the sensors is directly proportional to the **mass flow**.
* The tubes' **vibration frequency** allows the fluid's **density** to be calculated exactly.
* The instrument also incorporates a **temperature** sensor for internal thermal compensation and real-time monitoring.

---

## Why Choose Coriolis Technology?

* **Multivariable Measurement:** Get mass, density and temperature from a single instrument in the process line.
* **Independent of Flow Profile:** Unlike other technologies, true mass measurement is not affected by variations in the fluid's viscosity, pressure or density.
* **High Repeatability:** Ideal for critical chemical dosing and quality control applications where every gram counts.

---

## Technical Specifications and Process Conditions

### Measuring Range and Accuracy
* **Typical accuracy:** Up to **0.15%** on liquid flows, delivering world-class performance.
* **Mass flow range:** From **200 kg/h** to several thousand kg/h, depending on the selected model.
* **Density accuracy:** Up to **$\pm0.001 \text{ g/cm}^3$** for rigorous concentration control.

### Operating Conditions
* **Process temperature:** Wide working range from **$-200^\circ\text{C}$ to $320^\circ\text{C}$** (subject to model and installation).
* **Operating pressure:** Standard capacity of up to **10 MPa** (with options for higher pressures on technical request).

---

## Materials and Connectivity

### Construction Materials
* **Standard construction:** Tubes and body made of robust **Stainless Steel**.
* **Special materials:** Exotic alloy configurations available according to the fluid's corrosiveness and aggressiveness, to be defined by the application.

### Integration and Communications
Native compatibility with **PLC and SCADA** industrial control systems:
* **4-20 mA** analog output
* **RS-485** protocol

### Protection and Environment
* The protection rating (IP / NEMA) and hazardous-area (Ex) certifications are configured to suit the installation environment and are defined in detail in the commercial quotation.

---

## Typical Industrial Applications

1. **Critical reagent dosing:** Control and addition by mass of process reagents (such as xanthate, frother or pH modifiers) where maximum repeatability is required.
2. **Pulp and Paper Industry:** Continuous monitoring of flow and concentration/density in black liquor lines (*weak/strong*) for operational optimization.
3. **Non-Conductive Additives:** Accurate dosing of bleaching chemicals and complex process additives (including non-conductive compounds such as ASA) that rule out the use of magnetic flowmeters.
4. **Fuel Control:** Accurate measurement of diesel and other hydrocarbons for consumption management, audits and plant balances.
5. **Viscous and Non-Newtonian Fluids:** Ideal mass-based control for high-friction fluids or fluids with complex rheology such as syrups, oils and dense mixtures.
6. **Inline Quality Control:** Real-time tracking of density variations to determine purity, concentrations and final product quality.
7. **Custody Transfer Systems:** Loading, unloading and transfer where the critical value is knowing the exact true mass of the product, free of volume-related errors.

---

## Compatible Fluid Types

Thanks to its inertial physical principle, it is compatible with a vast range of industrial fluids:
* **Liquids** of any viscosity.
* **Gases** and vapors.
* **Slurries** and fluids with a high percentage of suspended solids.
* **Non-Newtonian fluids** (heavy sludge, pastes and concentrates).

Paddlewheel Flowmeters

# Paddlewheel Flowmeters and Flow Switches

**Paddlewheel flowmeters** are highly efficient, compact and cost-optimized volumetric measuring instruments, designed specifically for monitoring and controlling clean liquids in industrial environments. Their simple yet reliable mechanical principle makes them the standard solution for applications that require quick, direct flow control without complex electronic setups.

---

## Operating Principle

The instrument works through an **internal paddle** housed in the process line, which spins driven by the kinetic energy of the moving liquid. The rotation speed of this paddle is directly proportional to the fluid velocity.

Through an internal magnetic coupling that activates a **reed switch**, the system converts mechanical revolutions into a stable output signal to calculate total flow or trigger automatic flow/no-flow alarms. One of its greatest logistical advantages is that certain configurations allow mounting and installation **without interrupting the process or fully cutting the pipe**.

---

## When Is It the Right Solution for Your Plant?

Paddlewheel flow meters are fully recommended under the following conditions:
* **Clean Liquids:** Excellent performance in water and low-viscosity fluids with no solids.
* **Mechanical Safety Control:** Ideal when implementing automatic interlock systems, safety alarms or pump start/stop.
* **Cost-Optimized Installations:** When basic, reliable flow control is needed in secondary distribution networks.

*Restriction note:* Use is not recommended in abrasive or high-viscosity fluids, or those with a high load of suspended solids, as particles can jam or wear the shaft and the mechanical paddle.

---

## Technical Specifications and Process Conditions

### Measurement Capabilities and Ranges
* **Pipe Diameters:** Standard coverage for lines from **DN15 to DN100** (larger sizes available on technical request).
* **Typical Accuracy:** $\pm2\%$ of reading under standard flow conditions.
* **Repeatability:** $\pm1\%$ under stable operating conditions.
* **Pressure Loss:** Minimal line pressure drop of up to **3 psig**.

### Temperature and Pressure Limits
* **Process Temperature:**
* Standard Models: From **$-30^\circ\text{C}$ to $150^\circ\text{C}$**.
* Explosion-Proof Models: From **$-30^\circ\text{C}$ to $130^\circ\text{C}$**.
* **Maximum Operating Pressure:** Structural strength of up to **355 psig** (subject to model configuration).

---

## Materials and Industrial Connectivity

### Manufacturing Materials
* **Wetted Parts:** Paddle and internal parts made of high-strength **SUS304 stainless steel**.
* **Standard Process Connection:** **1/2" NPT** thread for quick, universal coupling.

### Output Signals and Integration (PLC / SCADA)
Our variants offer full integration flexibility in automated plants:
* **SPDT Dry-Contact Output (ON/OFF):** Perfect for acting as a direct flow switch for alarms or valve control.
* **Analog and Pulse Outputs:** Versions available with **4-20 mA** loop or pulse frequency for continuous totalization.
* **Protection and Safety:** **IP65** ingress protection with **NEPSI Ex d IIC T4-T6 Gb** explosion-proof certification options for hazardous areas.

---

## Typical Industrial Applications

1. **Water Network Monitoring:** Volumetric flow control in industrial water mains, internal distribution lines and treatment plants.
2. **HVAC and Climate Control Systems:** Measurement and flow switching in chilled or hot water circuits for ventilation and air-conditioning systems.
3. **Industrial Cooling Circuits:** Continuous flow monitoring in cooling towers and closed loops to prevent dry-running of critical equipment.
4. **Low-Viscosity Chemical Processes:** Basic dosing of clean liquids, compatible solvents and controlled process balances.
5. **Food and Beverage Industry:** Transfer and control of clear, homogeneous fluids such as process water, filtered juices or light oils free of pulp or solids.

Electromagnetic Flowmeters

Electromagnetic Flowmeters

# Electromagnetic Flowmeters: Industrial Flow Measurement Solutions

**Electromagnetic flowmeters** are high-precision instruments designed to measure the volumetric flow of conductive liquids in closed pipes. With no internal obstructions or moving parts, they deliver an extremely stable, reliable, low-maintenance measurement, making them the ideal choice for heavy-duty service.

---

## Operating Principle

The instrument operates under Faraday's law of induction: it generates a controlled **magnetic field** across the pipe. As a conductive fluid flows through it, the fluid induces a voltage proportional to its velocity, which is picked up by the **electrodes**. From this signal, the transmitter calculates and displays the flow rate accurately and in real time.

---

## When Is It the Right Solution for Your Process?

Electromagnetic flow meters are highly recommended in the following scenarios:

* **Liquids with suspended solids:** Excellent performance with abrasive or particle-laden fluids.
* **Operational continuity:** When the goal is to minimize maintenance downtime and ensure high availability.
* **Zero pressure loss:** Ideal for systems where the process cannot accept intrusive elements or pressure drops in the line.
* **Precise control and balancing:** When operational control or water balance demands high repeatability and technical accuracy.

---

## Technical Specifications and Process Conditions

### Measuring Range and Accuracy
* **Available sizes:** From **DN20 to DN1100** (larger sizes manufactured to project requirements).
* **Fluid velocity in the pipe:** From $\sim0.1 \text{ m/s}$ to $\sim10 \text{ m/s}$.
* **Typical accuracy:** From $\pm0.5\%$ of reading (with high-accuracy options up to $\pm0.2\%$).
* **Minimum fluid conductivity:** $\ge5 \ \mu\text{S/cm}$ (required for proper operation).
* **Repeatability:** Designed for optimal operational balance.

### Environmental and Operating Conditions
* **Fluid temperature:** Operating range from $-20^\circ\text{C}$ to $120^\circ\text{C}$.
* **Operating pressure:** Withstands up to **16 bar** (higher ratings available on special design).
* **Ambient temperature:** Withstands up to $70^\circ\text{C}$ (special versions for severe climates).

---

## Materials and Connectivity

### Construction Materials
To ensure chemical compatibility and wear resistance, we offer multiple configurations:
* **Electrodes:** 316L stainless steel, Hastelloy, Titanium and Tantalum.
* **Inner linings:** PTFE and Rubber (NBR / Neoprene), selected according to the fluid's abrasiveness.
* **Process connections:** Flanged (ANSI / JIS / DIN), Wafer type and Sanitary connections (Tri-Clamp / medical fittings).

### Signals and Communication Protocols
Direct compatibility for integration into **PLC, DCS and SCADA** systems:
* 4-20 mA analog output
* Pulse / frequency output
* RS-485 / Modbus protocol
* HART protocol (depending on model configuration)

---

## Typical Industrial Applications

1. **Industrial and process water lines:** Measurement in pump discharge systems, returns, bypasses and internal distribution networks.
2. **Water treatment:** Reliable monitoring in influents, effluents, recirculation and lines carrying diluted sludge.
3. **Fluids with complex particles:** Flow meters well suited to lines where water carries fines, sand, oxides or suspended material, avoiding the wear typical of technologies with moving parts.
4. **Mining and Chemicals:** Continuous monitoring of slurries, complex chemical solutions and diluted tailings.
5. **Closed cooling circuits:** Flow control and consumption balances in cooling towers and industrial thermal systems.
6. **Food and Pharmaceutical Industry:** Sanitary versions suited to product transfer, wash solutions and CIP/SIP processes.
7. **Energy Efficiency:** Accurate measurement of water consumption by area or equipment for audits, water balances and resource optimization.
8. **Harsh environments:** Suitable for outdoor use or plants with high humidity, vibration and dust thanks to their **IP67 / NEMA 4X** protection (with **IP68** options for flood-prone areas and Ex versions for hazardous areas).

---

## Compatible and Incompatible Fluids

| Fluids Suitable for Measurement | Fluids NOT Applicable |
| :--- | :--- |
| Industrial, treated and potable water | Non-conductive liquids |
| Effluents, wastewater and sludge | Pure hydrocarbons and oils |
| Slurry and liquids with suspended solids | Compressed gases |
| Conductive chemical solutions | Steam |

Differential Pressure Flowmeters

# Differential Pressure (DP) Flowmeters

**Differential pressure (DP) flowmeters** are classic, extremely robust instruments within industrial instrumentation. They are designed to measure the flow of liquids (both conductive and non-conductive), gases and steam with high stability, standing out for their ability to operate under extreme mechanical pressures and temperatures.

---

## Operating Principle

This technology determines flow from the pressure difference generated when the fluid passes through a restriction in the pipe (such as an orifice plate, a valve or a Venturi tube).

Based on Bernoulli's principle, as the fluid velocity increases at the restriction, the pressure decreases. By accurately measuring the pressure difference ($\Delta P$) between the upstream point ($P_1$) and the downstream point ($P_2$), the actual volumetric flow is calculated through the basic mathematical relationship:

$$Q = \sqrt{\frac{\Delta P}{\rho}}$$

Where:
* **$Q$:** Flow rate
* **$\Delta P$:** Pressure difference ($P_1 - P_2$)
* **$\rho$:** Fluid density

---

## Key Advantages of Differential Pressure (DP) Measurement

* **Fluid Versatility:** Suitable for measuring both conductive and non-conductive liquids, gases and steam.
* **High-Pressure Support:** The preferred engineering choice for processes with critical rated pressures of up to 40 MPa.
* **High Stability and Repeatability:** Delivers highly repeatable, stable measurement behavior in continuous flow regimes.
* **Wear Resistance:** Depending on the primary element configuration, certain models can handle fluids with solids or suspended particles without mechanical damage.

---

## Technical Specifications and Process Conditions

### Measuring Ranges and Performance
* **Pipe Diameters:** Standard range from **DN25 to DN500** (with custom design options up to **DN1200 or larger** depending on the project).
* **System Accuracy:** Maintains a typical accuracy range of **$\pm1\%$ to $\pm3\%$** of reading (subject to the specific primary element model and installation conditions).
* **Flow Range:** From $0.1 \text{ m}^3\text{/h}$ to thousands of cubic meters per hour.

### Operating Limits and Pressure Losses
* **Fluid Temperature:** Excellent thermal performance from **$-40^\circ\text{C}$ to $150^\circ\text{C}$**.
* **Operating Pressure:** Structural strength of up to **40 MPa** in high-end models.
* **Permanent Pressure Loss:** Its optimized geometric design generally keeps the pressure loss below **0.3 MPa**.

---

## Materials and Industrial Connectivity

### Available Materials
* **Wetted Components:** Components made as standard of **SUS316 Stainless Steel** to ensure a long service life against corrosion.
* **Process Connections:** Flanged connection per **ANSI, JIS or DIN** standards (with custom options for specific projects).
* **Installation Flexibility:** Supports local or remote mounting configurations to protect the electronics according to the plant's physical environment.

### Signal Integration (PLC / SCADA)
Equipped with smart transmitters that facilitate automation:
* **4-20 mA** analog output for continuous variable control.
* **Pulse or Frequency** output for totalization and fast monitoring.
* **RS-485 / Modbus and HART** industrial communication protocols.
* **Environmental Protection:** **IP67 / NEMA 4X** hermetic sealing with certified options for operation in **Hazardous Areas (Ex)**.

---

## Typical Industrial Applications

1. **Thermal Systems and Boilers:** Continuous measurement of steam, gas or air in boilers and turbines for optimal operational control and energy efficiency.
2. **Complex Fluid Handling:** Monitoring and measurement of slurries, dense mixtures and sludge circulation in internal plant movements.
3. **Refrigeration Systems:** Flow control in closed heat-exchange circuits and cooling towers to ensure overall efficiency.
4. **Water Networks and Infrastructure:** Flow control in process water lines, industrial water and effluent conveyance.
5. **Continuous Chemical Processes:** Flow instrumentation in reaction lines to ensure stability, efficiency and consistent production quality.
6. **Reagent Transfer:** Accurate measurement in transfer lines for industrial reagents and resins (depending on the technical configuration).

Thermodynamic Flowmeters

# Thermodynamic Flowmeters (EPT): Efficient Liquid Flow Measurement

**Thermodynamic flowmeters (EPT)** are a robust, highly reliable measurement solution for controlling complex industrial processes. These instruments are specially designed to overcome the limitations of other measurement technologies, delivering outstanding performance under dynamic flow variations, high levels of mechanical vibration and chemically challenging fluids.

---

## Operating Principle

The thermodynamic flowmeter bases its operation on the fluid's heat dissipation. The instrument has a **heated probe** immersed directly in the process line.

As the liquid flows through the pipe, it absorbs heat and causes a proportional change in the probe's temperature. The sensor accurately records this thermal change and instantly converts it into an output signal proportional to the actual volumetric flow.

---

## Technical Advantages of Thermodynamic Technology

* **High Reliability Under Vibration:** A highly stable mechanical structure that operates continuously on lines subject to mechanical shock and severe vibration.
* **Chemical and Mechanical Resistance:** Built with high-quality materials suited to abrasive or corrosive fluids.
* **Excellent Response Dynamics:** Fast response time to quickly capture sudden flow changes.
* **Extreme Environmental Protection:** Ingress protection rating designed to operate in the wettest, most demanding industrial conditions.

---

## Technical Specifications and Process Conditions

### Measuring Ranges and Performance
* **Pipe Diameters:** Standard application range from **DN15 to DN300**. Engineering adaptations for large diameters of up to **DN600 or larger** are available on prior request.
* **System Accuracy:** Guarantees an accuracy margin of **$\pm2\%$ of reading** under standard field conditions.
* **Velocity Range:** Effective, stable measurement at fluid velocities from **$10\text{ cm/s}$ to $400\text{ cm/s}$**.
* **Response Time:** Fast switching and reading update between **2 and 5 seconds**.

### Operating Limits
* **Operating Pressure:** Extreme structural strength of up to **100 bar**.
* **Fluid Temperature:** Continuous working range of **$-25^\circ\text{C}$ to $150^\circ\text{C}$** depending on the sensor model.
* **Ambient Temperature:** Safely withstands extreme climate ranges from **$-25^\circ\text{C}$ to $80^\circ\text{C}$**.

---

## Materials and Industrial Connectivity

### Materials and Connections
* **Wetted Parts:** Measuring probe made entirely of **316L Stainless Steel**, a material inert to chemical corrosion and mechanical wear.
* **Process Connection:** Standard **1/2" NPT** thread (with customization options per project specification).
* **Electrical Connection:** Secure, robust **M12 (6-pin)** port.

### Integration and Control Signal
* **Analog Output:** Standard **4-20 mA** signal for easy integration with PLC and SCADA systems.
* **Digital Communication:** Native connectivity via the **RS-485** industrial protocol.
* **Additional Temperature Measurement:** Integrated option to record process temperature alongside flow measurement.
* **Electrical Safety:** Built-in electronic protection against overloads and short circuits.
* **Protection and Washdown:** **IP68 / IP69K** ingress ratings, ideal for withstanding atmospheres with high dust concentration, extreme humidity or high-pressure washdown cycles.

---

## Compatible Fluids and Typical Applications

This instrument is highly versatile and optimized to work with:
* **Conductive Liquids:** Water, aqueous solutions and fluids with high water content.
* **Fluids with Impurities:** Liquids carrying particles or suspended solids, operating continuously without any impact on performance.
* **Corrosive or Abrasive Fluids:** An ideal solution for hard-to-measure lines where traditional electromagnetic flow technologies face mechanical or chemical limitations.

### Common Application Areas
1. **Water Treatment:** Flow monitoring in influent and effluent lines and in the pumping of liquids with a high density of suspended solids.
2. **Heat Exchange Systems:** Flow control and monitoring in cooling towers and closed industrial refrigeration loops.
3. **Highly Variable Lines:** Measurement of fluids subject to rapid flow changes, or in plants with high structural vibration due to industrial pumping.

Ultrasonic Flowmeters

# Ultrasonic Flowmeters: High-Precision Non-Intrusive Measurement

**Ultrasonic flowmeters** are one of the most versatile and innovative flow measurement technologies on the industrial market. Because they rely on the transmission of acoustic waves, they can quantify liquid flow with full accuracy without placing any obstructive elements inside the pipe. This completely eliminates hydraulic pressure loss and minimizes instrument wear.

---

## Operating Principle and Technologies

Our ultrasonic meters operate under two specific physical principles depending on the characteristics of the process fluid:

* **Transit Time Mode:** Two externally mounted transducers alternately transmit and receive acoustic signals. By comparing the difference in transit time of the waves traveling with and against the flow, the system calculates the fluid velocity with high accuracy. It is used mainly in clean liquids.
* **Doppler Mode:** Aimed at fluids containing solid particles or suspended gas bubbles. The emitted ultrasonic waves are reflected by these moving impurities; the resulting change in the frequency of the reflected signal (Doppler effect) is used to determine the flow velocity.

---

## Advantages of External (Clamp-On) Mounting

* **Installation Without Interruption:** The clamp-on system lets you fix the sensors to the outside of the pipe without stopping production, cutting the piping or drilling the line.
* **Zero Pressure Loss:** Since no intrusive sensors are required, it creates no flow resistance or pressure drop in the system.
* **Simplified Maintenance:** With no direct contact with aggressive chemicals, sludge or sand, sensor wear is nil, drastically reducing technical interventions.
* **Diameter Versatility:** A single transducer kit can be reconfigured to measure different pipe diameters.

---

## Technical Specifications and Process Conditions

### Measurement Capabilities and Performance
* **Pipe Diameter Range:** Standard coverage from **DN15 to DN600** for clamp-on models. Special adaptations are available for large conduits of up to **DN1200 or larger** on project request.
* **Operating Velocity in the Pipe:** From a minimum of **0.03 m/s up to 12 m/s**.
* **System Accuracy:** Typical accuracy of **$\pm1\%$ of reading** under stable operating conditions.
* **Repeatability:** Outstanding performance and measurement consistency thanks to its solid-state design with no moving parts.

### Operating and Protection Limits
* **Fluid Temperature:** Standard operating range from **$-25^\circ\text{C}$ to $70^\circ\text{C}$** (subject to the selected model and technology).
* **Operating Pressure:** Withstands up to **16 bar** as standard in inline systems (with configurations for higher pressures on request).
* **Enclosure Protection Rating:** Standard **IP67 / NEMA 4X** hermetic sealing with an **IP68** option for flood-prone areas, wet chambers or outdoor use.
* **Certification:** Versions certified for Hazardous Areas (Ex) are available depending on the application model.

---

## Materials and Industrial Connectivity

### Pipe Compatibility
Our solutions are compatible with a wide range of sound-conducting pipe materials:
* Stainless steel
* PVC
* Cast iron
* Other corrosion- and abrasion-resistant materials

### Mounting Modes
* **Clamp-On (External):** Mounting with no direct contact for diameters from DN15 to DN600.
* **Inline:** Flanged versions or versions with mechanical adapters per international ANSI, DIN or JIS standards.

### Signal Integration (PLC / SCADA)
Electronic transmitters ready for automation and distributed control (DCS) networks:
* **4-20 mA** analog output
* **RS-485 (Modbus)** digital communication and **HART** protocol
* Configurable **Pulse** output

---

## Compatible Fluid Types

* **Clean Liquids (Transit Time):** Potable water, treated process water, industrial solvents and light oils.
* **Liquids with Solids or Aeration (Doppler):** Wastewater, mining slurries, industrial effluents, sludge and mixtures with suspended bubbles.
* **Highly Viscous Fluids:** Heavy oils, dense sludge and high-viscosity chemicals (subject to process conditions and sensor technology).

---

## Typical Plant Applications

1. **Energy Audits and Diagnostics:** Temporary, portable measurement on existing pipes for water balances, plant commissioning or pump curve validation without interrupting the flow.
2. **Large-Diameter Measurement:** Control of main consumption and balancing by area in mains from DN200 to DN1200, avoiding costly modifications to the pipe infrastructure.
3. **Cooling Circuits:** Monitoring of recirculation flow in closed loops and industrial cooling towers to ensure heat transfer.
4. **Abrasive or Aggressive Chemical Fluids:** Measurement in corrosive effluents, slurries or chemicals with bubbles where conventional intrusive sensors would suffer accelerated mechanical wear.
5. **Auxiliary Services and Recirculation:** Flow control in washing, filtration and general service lines that require low maintenance.

Vortex Flowmeters

# Vortex Flowmeters: Flow Measurement for Steam, Gases and Liquids

**Vortex flowmeters** are recognized in industry for their extraordinary robustness and their ability to handle one of the most demanding flow measurement applications in the plant: the control of **steam** (both saturated and superheated), as well as utility gases and clean liquids or liquids containing fines. Their physical principle makes them the standard technology for boiler energy balances, optimizing consumption and heat recovery.

---

## Operating Principle

The Vortex flowmeter works by detecting swirls or vortices that form naturally when the flow is deliberately obstructed. The instrument has a static component called a **bluff body** (or obstacle) installed across the pipe.

As the fluid passes this body, alternating vortices are generated on each side. The frequency at which these vortices form is directly proportional to the fluid velocity in the line. A highly sensitive **piezoelectric sensor** registers the pressure fluctuations caused by these vortices and converts them into electrical signals that the transmitter processes to accurately calculate the volumetric flow and, depending on the instrument's configuration, the mass flow in the line.

---

## Main Advantages of the Vortex Flow Meter

* **Advanced Steam Measurement:** The most reliable technology for controlling saturated and superheated steam, tolerating extreme thermal shock.
* **Low Pressure Loss:** Its design creates minimal restriction to the fluid, which means lower energy consumption in pumping and compression systems.
* **High Operational Availability:** With no moving parts exposed to direct mechanical wear, it substantially reduces preventive maintenance costs and plant downtime.
* **Fluid Versatility:** A single physical principle is suitable for measuring low-viscosity liquids, compressed air, inert or process gases, and utility steam.

---

## Technical Specifications and Process Conditions

### Measuring Ranges and Accuracy
* **Pipe Diameters:** Standard coverage from **DN15 to DN300** (with special designs for large diameters available on technical project request).
* **Typical Operating Accuracy:** Accuracy margin between **$\pm1\%$ and $\pm2\%$** of reading, subject to the line's operating conditions.
* **Flow Range:** Continuous, stable measurement from $0.1\text{ m}^3\text{/h}$ to thousands of cubic meters per hour.
* **Flow Velocity in the Pipe:** Wide operating range from **$0.3\text{ m/s}$ to $30\text{ m/s}$** depending on the nominal piping diameter.

### Extreme Operating Conditions
* **Fluid Temperature:** Withstands extreme cryogenic and thermal temperature ranges from **$-200^\circ\text{C}$ to $500^\circ\text{C}$**.
* **Maximum Operating Pressure:** High-strength structural design to operate safely at pressures of up to **1500 psig**.

---

## Materials and Industrial Connectivity

### Manufacturing Materials
* **Body and Sensors:** Made as standard of **SUS316 Stainless Steel** with high chemical and thermal resistance, with Hastelloy or Carbon Steel options for specific applications.
* **Process Connections:** Flange couplings per international **ANSI, JIS or DIN** standards.
* **Mounting Flexibility:** Electronics available in compact local mounting or remote configuration to protect the transmitter from severe radiant heat.

### Signals and Integration (PLC / SCADA)
Equipped with advanced digital transmitters ready for plant automation:
* Traditional **4-20 mA** analog output.
* **Pulse or Frequency** output for fast loop control.
* Native **RS-485 / Modbus and HART** communication protocols.
* **Environmental Protection:** **IP67 / NEMA 4X** ingress rating with certified options for operation in hazardous areas under **ATEX, IECEx or FM** standards.

---

## Typical Plant Applications

1. **Steam Distribution Networks:** Measurement of utility steam for consumption balancing at main headers, distribution branches and end-use points across the plant.
2. **Equipment Thermal Efficiency:** Steam flow control to heat exchangers, heaters and direct injection lines for energy efficiency audits.
3. **Air and Utility Gas Monitoring:** Measurement of instrument air, process air and auxiliary plant gases.
4. **Cooling and Industrial Water:** Flow control in process water networks, discharge lines, returns and closed circuits associated with cooling towers.
5. **Condensate Recovery:** Measurement of hot condensate returns to optimize the boiler feedwater cycle.
6. **Fluids Containing Fines:** Measurement in processes involving water with suspended particles or variable quality, where a robust solution that does not suffer from clogging is required.

Industrial Flow Switches

# Industrial Flow Switches

**Flow switches** are critical safety components designed to protect machinery, pumps and piping systems. Unlike conventional flowmeters, these devices do not perform continuous flow measurement; instead, they deliver a fast ON/OFF switching signal when the flow of a fluid rises above, falls below or reaches a predetermined setpoint.

---

## Operating Principle and Technologies

Depending on the design and the requirements of the industrial process, we offer multiple technologies to ensure safe switching:

* **Mechanical Paddle Switches:** Actuated by the thrust and physical displacement the fluid exerts on an internal paddle suspended in the line.
* **Thermal Dispersion Switches:** Electronic devices with no moving parts that compare the fluid's heat dissipation through integrated temperature sensors, offering high wear resistance.
* **Duct Air Switches:** Designed specifically to capture air velocity in ventilation and HVAC systems using light paddle mechanisms.

---

## When Is It the Right Solution for Your Plant?

A flow switch is essential in the following situations:
* **Equipment Protection:** Active prevention of dry-running in centrifugal pumps, protecting mechanical seals and impellers.
* **System Enablement (Interlock):** Ensuring a minimum cooling or lubrication flow exists before allowing high-power motors or compressors to start.
* **Safety Alarms:** Automatic activation of visual or audible alerts on a sudden loss of flow ("no-flow") in the process line.

---

## General Technical Specifications

### Operating Ranges by Fluid
* **Liquids (Water):** Velocity detection from $1 \text{ cm/s}$ to $150 \text{ cm/s}$. Actuation available from low flow rates ($\sim5 \text{ gpm}$).
* **Liquids (Oils):** Velocity detection from $3 \text{ cm/s}$ to $300 \text{ cm/s}$.
* **Air and Gases in Ducts:** Typical operating velocities from $1.9 \text{ m/s}$ up to a maximum allowed of $12.7 \text{ m/s}$.

### Supported Process Conditions
* **Mechanical Paddle Models:** Withstand operating pressures of up to **24 bar** and process temperatures from **$-30^\circ\text{C}$ to $150^\circ\text{C}$**.
* **Thermal Dispersion Models:** Standard supply of 19 to 30 Vdc, thermal resistance of **$-20^\circ\text{C}$ to $80^\circ\text{C}$** (with special versions for wider ranges) and maximum pressure of up to **100 bar**.

---

## Construction Materials and Connectivity

### Available Materials
* **Wetted Parts:** Standard construction in stainless steel (**SUS304, SUS316 and SUS316L**) for maximum chemical compatibility.
* **External Housings:** Available in stainless steel, robust aluminum alloys or high-strength industrial plastics.
* **Non-Intrusive Detection:** Options made of engineering plastic (Polypropylene - PP) that mount externally on non-metallic pipes, ideal for aggressive liquids without needing to drill the pipe.
* **Air Applications:** Internal components configurable in stainless steel or bronze.

### Output Signals and Integration
* **SPDT Dry-Contact Output (ON/OFF):** The standard for mechanical and air switches, making it easy to connect to safety relays or PLC digital inputs.
* **PNP/NPN Electronic Output (Open Collector):** Common in thermal dispersion switches for high-speed switching and integration with SCADA systems.
* **Local Indication:** Fitted with status LEDs for quick field verification.
* **Environmental Protection:** **IP65** (paddle) and **IP67** (thermal insertion) ratings with certified options for hazardous areas (Ex).

---

## Typical Industrial Applications

1. **Operating Interlocks:** Confirmation of minimum flow to enable the safe start-up of critical downstream equipment.
2. **Process Pump Protection:** Prevention of cavitation and catastrophic failures caused by insufficient recirculation or a complete absence of liquid.
3. **Cooling and Refrigeration Loops:** Constant verification of utility water circulation in heat exchangers and HVAC installations.
4. **Air Duct Detection:** Control of fans, industrial blowers and air injectors for HVAC and forced ventilation systems.
5. **Non-Intrusive Detection in Plastic Pipes:** Safe monitoring of liquid presence in lines where drilling the piping is not feasible due to chemical or hygiene risks.

About this category

Industrial Flowmeters and Flow Meters: Reliable Measurement Solutions

Accurate measurement and control of fluid flow are fundamental pillars for ensuring the efficiency, safety and profitability of any industrial process. Our line of flowmeters and flow meters covers a wide range of technologies designed to meet the most demanding operational challenges, from potable water monitoring to the control of highly abrasive or viscous fluids, compressed gases or saturated steam.


Flow Measurement Technologies

There is no single universal flowmeter for every process. To help you find the right instrument, we classify our solutions by their physical principle and design application:

  • Electromagnetic Flowmeters: The definitive choice for conductive liquids, industrial water, effluents and slurries with suspended solids (heavy duty). With no obstructions or moving parts, they offer zero pressure loss and minimal maintenance.
  • Coriolis Flowmeters: The highest-precision instruments on the market. They directly measure mass flow, density and temperature in a single installation, making them indispensable in custody transfer systems and highly viscous fluids.
  • Ultrasonic Flowmeters: Non-intrusive measurement using transit-time or Doppler technology. Ideal for energy audits or installations where the pipe cannot be cut to intervene in the process.
  • Vortex Flowmeters: Designed especially for reliable measurement of fluids at high velocities, and the standard, most efficient technology for steam (saturated and superheated), gases and low-viscosity liquids.
  • Differential Pressure Flow Meters: A classic, robust technology based on primary elements (such as orifice plates or Venturi tubes). Excellent for standardized liquid, gas and steam applications at high pressures and temperatures.
  • Paddlewheel Flowmeters: Compact, economical mechanical instruments, ideal for monitoring clean flows in industrial water lines, cooling systems and simple dosing control.
  • Thermal Mass Flowmeters: Based on thermal dispersion, they are highly sensitive and accurate for direct mass flow measurement of compressed air, flue gases and process gases, with no need for external compensation.
  • Flow Switches: Automatic switches designed to protect pumps and piping. They reliably detect the presence or absence of flow (flow/no-flow alarm) to prevent costly dry-running.

Key Criteria for Selecting a Flow Meter

To ensure optimal performance and a long service life for the instrument, our engineering team evaluates the following variables on every project:

  1. Fluid properties: Fluid type (liquid, gas or steam), viscosity, electrical conductivity, temperature, pressure and the presence of solids or aggressive chemicals.
  2. Accuracy requirements: Need for volumetric or mass (by weight) measurement, and the accuracy levels demanded by process control.
  3. Environment and installation: Pipe diameter, available straight runs for flow stabilization, required connectivity (4-20 mA, Modbus, HART) and protection ratings (IP67, IP68 or Ex hazardous areas).

Multi-Sector Applications

Our flow instrumentation solutions are present in the most demanding industrial sectors:

  • Water Treatment and Management: Monitoring in potable water plants, industrial effluents, bypasses and distribution networks.
  • Mining and Pulp: Control of dense slurries, diluted tailings, xanthate dosing and black liquor lines.
  • Food, Beverage and Pharmaceutical: Versions with sanitary connections suited to CIP/SIP cleaning processes and hygienic product transfers.
  • Energy and Fuels: Steam management in boilers, water balances in cooling systems, diesel consumption control and energy efficiency projects.
Catalog

Products in Industrial Flowmeters and Flow Meters

7 products
Flanged Electromagnetic Flowmeters for Industrial Processes
Electromagnetic Flowmeters

Flanged Electromagnetic Flowmeters for Industrial Processes

Flanged (ANSI/DIN) electromagnetic flowmeters designed for demanding flow control of conductive liquids. A robust solution with no internal obstructions or moving parts, ideal for industrial water, effluents, slurries and chemical solutions in heavy-duty applications.

View specifications
Sanitary Tri-Clamp Electromagnetic Flowmeter
Electromagnetic Flowmeters

Sanitary Tri-Clamp Electromagnetic Flowmeter

Sanitary-grade electromagnetic flowmeter with quick Tri-Clamp connection for accurate flow measurement in the food, beverage and pharmaceutical industries. Features a polished stainless steel body and a liner suited to CIP/SIP cleaning and sanitizing processes, ensuring maximum product safety.

View specifications
Electromagnetic Flowmeter with Remote Sensor
Electromagnetic Flowmeters

Electromagnetic Flowmeter with Remote Sensor

Electromagnetic flowmeter with a remote sensor configuration for accurate flow measurement in large diameters and severe operating conditions. Built with a robust flanged or Wafer-type body, it is ideal for installation in flood-prone areas, underground chambers or high-vibration environments, keeping the electronics protected.

View specifications
Industrial Coriolis Flowmeter (Mass Flow and Density Meter)
Coriolis Flowmeters

Industrial Coriolis Flowmeter (Mass Flow and Density Meter)

High-end industrial Coriolis flowmeter for direct, simultaneous measurement of mass flow, density and temperature in complex fluids. Its advanced, high-sensitivity inertial design delivers outstanding accuracy of up to 0.15%, making it the ideal solution for fuel control, reagent dosing and custody transfer.

View specifications
Industrial Low-Profile Coriolis Flowmeter with Remote Sensor
Coriolis Flowmeters

Industrial Low-Profile Coriolis Flowmeter with Remote Sensor

Remote-configuration, low-profile Coriolis flowmeter with a reinforced protective housing for accurate measurement of mass flow, density and temperature. Its design with no integral converter protects the electronics from thermal shock, pulsation and direct mechanical vibration from the pipe, and eases installation in compact racks.

View specifications
High-Accuracy Coriolis Flowmeter (U-Tube Design)
Industrial Flowmeters and Flow Meters

High-Accuracy Coriolis Flowmeter (U-Tube Design)

High-performance Coriolis flowmeter with U-shaped geometry, optimized for direct mass measurement of critical fluids. Its geometry maximizes sensitivity to the Coriolis force, delivering superior accuracy for precision dosing, inline quality control and custody transfer applications.

View specifications
Industrial Paddle-Type Flow Switch
Paddlewheel Flowmeters

Industrial Paddle-Type Flow Switch

Mechanical paddle-type flow switch designed for automatic detection of the presence or absence of flow in industrial pipelines. With robust stainless steel construction and an SPDT dry-contact output, it is the ideal solution for protecting pumps against dry running and for safety interlocking in HVAC systems and water networks.

View specifications