Industrial Flow Switches
Industrial flow switches designed to detect the presence or absence of flow in liquids and gases. Robust solutions for interlock systems, safety alarms and pump dry-run protection, with SPDT and PNP/NPN outputs and highly reliable mechanical and thermal technologies.
Industrial Flow Switches
Flow switches are critical safety components designed to protect machinery, pumps and piping systems. Unlike conventional flowmeters, these devices do not perform continuous flow measurement; instead, they deliver a fast ON/OFF switching signal when the flow of a fluid rises above, falls below or reaches a predetermined setpoint.
Operating Principle and Technologies
Depending on the design and the requirements of the industrial process, we offer multiple technologies to ensure safe switching:
- Mechanical Paddle Switches: Actuated by the thrust and physical displacement the fluid exerts on an internal paddle suspended in the line.
- Thermal Dispersion Switches: Electronic devices with no moving parts that compare the fluid's heat dissipation through integrated temperature sensors, offering high wear resistance.
- Duct Air Switches: Designed specifically to capture air velocity in ventilation and HVAC systems using light paddle mechanisms.
When Is It the Right Solution for Your Plant?
A flow switch is essential in the following situations:
- Equipment Protection: Active prevention of dry-running in centrifugal pumps, protecting mechanical seals and impellers.
- System Enablement (Interlock): Ensuring a minimum cooling or lubrication flow exists before allowing high-power motors or compressors to start.
- Safety Alarms: Automatic activation of visual or audible alerts on a sudden loss of flow ("no-flow") in the process line.
General Technical Specifications
Operating Ranges by Fluid
- Liquids (Water): Velocity detection from $1 \text{ cm/s}$ to $150 \text{ cm/s}$. Actuation available from low flow rates ($\sim5 \text{ gpm}$).
- Liquids (Oils): Velocity detection from $3 \text{ cm/s}$ to $300 \text{ cm/s}$.
- Air and Gases in Ducts: Typical operating velocities from $1.9 \text{ m/s}$ up to a maximum allowed of $12.7 \text{ m/s}$.
Supported Process Conditions
- Mechanical Paddle Models: Withstand operating pressures of up to 24 bar and process temperatures from $-30^\circ\text{C}$ to $150^\circ\text{C}$.
- Thermal Dispersion Models: Standard supply of 19 to 30 Vdc, thermal resistance of $-20^\circ\text{C}$ to $80^\circ\text{C}$ (with special versions for wider ranges) and maximum pressure of up to 100 bar.
Construction Materials and Connectivity
Available Materials
- Wetted Parts: Standard construction in stainless steel (SUS304, SUS316 and SUS316L) for maximum chemical compatibility.
- External Housings: Available in stainless steel, robust aluminum alloys or high-strength industrial plastics.
- Non-Intrusive Detection: Options made of engineering plastic (Polypropylene - PP) that mount externally on non-metallic pipes, ideal for aggressive liquids without needing to drill the pipe.
- Air Applications: Internal components configurable in stainless steel or bronze.
Output Signals and Integration
- SPDT Dry-Contact Output (ON/OFF): The standard for mechanical and air switches, making it easy to connect to safety relays or PLC digital inputs.
- PNP/NPN Electronic Output (Open Collector): Common in thermal dispersion switches for high-speed switching and integration with SCADA systems.
- Local Indication: Fitted with status LEDs for quick field verification.
- Environmental Protection: IP65 (paddle) and IP67 (thermal insertion) ratings with certified options for hazardous areas (Ex).
Typical Industrial Applications
- Operating Interlocks: Confirmation of minimum flow to enable the safe start-up of critical downstream equipment.
- Process Pump Protection: Prevention of cavitation and catastrophic failures caused by insufficient recirculation or a complete absence of liquid.
- Cooling and Refrigeration Loops: Constant verification of utility water circulation in heat exchangers and HVAC installations.
- Air Duct Detection: Control of fans, industrial blowers and air injectors for HVAC and forced ventilation systems.
- Non-Intrusive Detection in Plastic Pipes: Safe monitoring of liquid presence in lines where drilling the piping is not feasible due to chemical or hygiene risks.
There are no products available in this category yet.