Thermodynamic Flowmeters
Thermodynamic flowmeters (EPT) for highly reliable flow measurement in conductive, corrosive or impurity-laden liquids. Instruments designed to operate stably under extreme conditions of up to 100 bar pressure, severe mechanical vibration and rapid flow variations. IP68/IP69K protection withstands high-pressure washdowns.
Thermodynamic Flowmeters (EPT): Efficient Liquid Flow Measurement
Thermodynamic flowmeters (EPT) are a robust, highly reliable measurement solution for controlling complex industrial processes. These instruments are specially designed to overcome the limitations of other measurement technologies, delivering outstanding performance under dynamic flow variations, high levels of mechanical vibration and chemically challenging fluids.
Operating Principle
The thermodynamic flowmeter bases its operation on the fluid's heat dissipation. The instrument has a heated probe immersed directly in the process line.
As the liquid flows through the pipe, it absorbs heat and causes a proportional change in the probe's temperature. The sensor accurately records this thermal change and instantly converts it into an output signal proportional to the actual volumetric flow.
Technical Advantages of Thermodynamic Technology
- High Reliability Under Vibration: A highly stable mechanical structure that operates continuously on lines subject to mechanical shock and severe vibration.
- Chemical and Mechanical Resistance: Built with high-quality materials suited to abrasive or corrosive fluids.
- Excellent Response Dynamics: Fast response time to quickly capture sudden flow changes.
- Extreme Environmental Protection: Ingress protection rating designed to operate in the wettest, most demanding industrial conditions.
Technical Specifications and Process Conditions
Measuring Ranges and Performance
- Pipe Diameters: Standard application range from DN15 to DN300. Engineering adaptations for large diameters of up to DN600 or larger are available on prior request.
- System Accuracy: Guarantees an accuracy margin of $\pm2%$ of reading under standard field conditions.
- Velocity Range: Effective, stable measurement at fluid velocities from $10\text{ cm/s}$ to $400\text{ cm/s}$.
- Response Time: Fast switching and reading update between 2 and 5 seconds.
Operating Limits
- Operating Pressure: Extreme structural strength of up to 100 bar.
- Fluid Temperature: Continuous working range of $-25^\circ\text{C}$ to $150^\circ\text{C}$ depending on the sensor model.
- Ambient Temperature: Safely withstands extreme climate ranges from $-25^\circ\text{C}$ to $80^\circ\text{C}$.
Materials and Industrial Connectivity
Materials and Connections
- Wetted Parts: Measuring probe made entirely of 316L Stainless Steel, a material inert to chemical corrosion and mechanical wear.
- Process Connection: Standard 1/2" NPT thread (with customization options per project specification).
- Electrical Connection: Secure, robust M12 (6-pin) port.
Integration and Control Signal
- Analog Output: Standard 4-20 mA signal for easy integration with PLC and SCADA systems.
- Digital Communication: Native connectivity via the RS-485 industrial protocol.
- Additional Temperature Measurement: Integrated option to record process temperature alongside flow measurement.
- Electrical Safety: Built-in electronic protection against overloads and short circuits.
- Protection and Washdown: IP68 / IP69K ingress ratings, ideal for withstanding atmospheres with high dust concentration, extreme humidity or high-pressure washdown cycles.
Compatible Fluids and Typical Applications
This instrument is highly versatile and optimized to work with:
- Conductive Liquids: Water, aqueous solutions and fluids with high water content.
- Fluids with Impurities: Liquids carrying particles or suspended solids, operating continuously without any impact on performance.
- Corrosive or Abrasive Fluids: An ideal solution for hard-to-measure lines where traditional electromagnetic flow technologies face mechanical or chemical limitations.
Common Application Areas
- Water Treatment: Flow monitoring in influent and effluent lines and in the pumping of liquids with a high density of suspended solids.
- Heat Exchange Systems: Flow control and monitoring in cooling towers and closed industrial refrigeration loops.
- Highly Variable Lines: Measurement of fluids subject to rapid flow changes, or in plants with high structural vibration due to industrial pumping.
There are no products available in this category yet.
View the full catalog