RF Admittance (Capacitive) Level Transmitters

Continuous RF admittance and capacitance level transmitters for liquids, powders and granulates. Designed with coating rejection technology, they withstand temperatures up to 200 °C and pressures up to 40 atm, offering robust measurement and standard 4-20 mA outputs with HART protocol.

About this category

RF Admittance (Capacitive) Level Transmitters

RF admittance (radio frequency) or capacitive level transmitters are high-technology instruments designed for continuous level measurement in a wide variety of industrial applications. This technology stands out for its versatility in handling both liquids and bulk solids (powders and granulates), and excels in demanding environments thanks to advanced functions that ignore mechanical buildup of material on the sensing element.


Operating Principle

The system determines the tank level by measuring electrical variables proportional to the fill volume:

  1. Dielectric Variation: The instrument constantly detects the change in capacitance or electrical admittance generated between the installed sensing probe and the metal tank wall (or a secondary reference electrode).
  2. Material Effect: As the fluid or solid rises or falls, it displaces air and acts as a variable dielectric medium around the rod or cable, changing the picofarads (pF) recorded.
  3. Conversion and Coating Rejection: The electronic circuit converts the electrical range (which varies from tens to thousands of pF) into a linear level signal. Advanced models incorporate active shield technology (coating rejection / guard) to suppress bridging or coating effects from sticky materials, eliminating false readings caused by buildup.

Technical recommendation: In processes handling water-based conductive liquids, a probe with polymer insulation must be used to prevent short circuits from wetting and to reduce false indications caused by residual wet films.


Key Advantages of RF Admittance

  • Immunity to Buildup: The coating rejection function allows accurate measurement of wet materials or materials that tend to stick to the probe.
  • Media Versatility: Suitable for measuring conductive and non-conductive products, including fine powders with airborne dust.
  • High-Temperature Construction: Ceramic insulators available to withstand thermal shock and instrumentation in severe processes.
  • No Moving Parts: Its solid-state design minimizes predictive maintenance requirements.

Technical Specifications and Process Conditions

Measuring Ranges and Probe Configuration

  • Rod-Type Probes: Reference physical length of around 1.2 to 1.5 meters.
  • Suspended Cable Probes: Typical measuring length of up to 15 meters, with engineering configurations able to reach up to 50 meters of vertical range.
  • Transmitter Electrical Range: Reading capacity in the order of tens to thousands of pF (picofarads), adapting to the model and the product being measured.

Operating and Environmental Limits

  • Operating Temperature: From cryogenic or standard ranges of $-40^\circ\text{C}$ to $85^\circ\text{C}$ in base versions, extending up to $200^\circ\text{C}$ in high-temperature models.
  • Process Pressure: Mechanical strength of 32 to 40 atm depending on connection and body type.
  • Industrial Output and Communication: Standard 4-20 mA (2-wire) current loop with digital integration option via HART protocol.
  • Sealing and Hygiene Rating: Designed to IP65 protection standards, with variants certified EX (Explosion Proof).

Available Materials

  • Sensing Element: Probe core made of high-specification stainless steel.
  • Insulators and Chemical Coatings: Protective sleeves in PFA, Kynar (PVDF) and advanced engineering polymers for chemical compatibility and insulation in conductive liquids.
  • Superior Thermal Insulation: Ceramic connectors and barriers for high-temperature processes.

Typical Industrial Applications

  1. Silos and Hoppers with Bulk Solids: Continuous inventory monitoring in powder and granulate silos with dense dusty atmospheres that require a robust contact sensor.
  2. Wet or Sticky Materials: Accurate measurement in product lines with high probe adhesion using electronics with coating rejection.
  3. Metal and Non-Conductive Tanks: Direct instrumentation using the tank walls as reference, or installation with a reference electrode in plastic or non-conductive vessels.
  4. Processes with Product Changeover: Measurement in multi-product tanks that allow local or remote recalibration according to the change in the material's dielectric constant.
  5. Water-Based Conductive Liquids: Level control in aqueous solutions using insulated probes to eliminate the error from a wet film on the sensor surface.

There are no products available in this category yet.

View the full catalog