Guided Wave Radar (GWR/TDR) Level Transmitter

Guided wave radar (GWR/TDR) continuous level transmitter for stable measurement of liquids and solids and interface control. With an operating range of up to 20 meters, it withstands temperatures from -40 °C to 230 °C and pressures up to 60 bar, ensuring full accuracy in the presence of steam, foam, condensation and complex internal geometries.

About this category

Guided Wave Radar (GWR/TDR) Level Transmitter

The guided wave radar level transmitter (GWR, also known as TDR) is one of the most stable and accurate continuous measurement technologies on the industrial market. By channeling electromagnetic pulses along a rigid or flexible physical guide, this instrument completely eliminates signal scattering and the false echoes caused by tank obstructions, delivering outstanding performance in environments with extreme turbulence, heavy foam or dense vapors.


Operating Principle

Guided wave technology bases its operation on time-domain reflectometry:

  1. Pulse Emission: The electronic head emits low-energy microwave pulses that travel, guided along a physical probe (rod or cable), into the tank.
  2. Reflection from Dielectric Change: When the signal hits the product surface, it detects an abrupt change in the medium's dielectric constant, causing part of the pulse to reflect and return along the same probe to the sensor.
  3. Conversion and Interface Control: The digital transducer calculates the total round-trip transit time with maximum fidelity and converts it into a continuous level reading. In addition, if the remaining pulse continues down through a light non-conductive phase (such as oil), a second reflection is generated when it hits the heavy conductive phase (such as water), allowing simultaneous interface measurement between two liquids.

Key Advantages of GWR Guided Radar

  • Immunity to Space Disturbances: Guiding the signal prevents the microwaves from scattering, allowing the instrument to be installed a few centimeters from the tank walls or in complex internal geometries with heating coils, side inlets or mechanical agitators.
  • Process-Independent Performance: Maintains impeccable accuracy even under dense layers of surface foam, boiling, airborne dust clouds or saturated steam and condensation on the head.
  • Simultaneous Interface Measurement: An optimal solution for decanters and water/hydrocarbon phase separators.
  • Low Density Impact: The reading depends solely on the medium's surface dielectric constant, unaffected by variations in the product's density or specific gravity.

Technical Specifications and Process Conditions

Measurement Capabilities and Ranges

  • Continuous Level Measurement: Linear coverage scale from 0.5 to 20 meters in height.
  • Interface Layer Measurement: Phase detection range of up to 10 meters of vertical length.
  • Dynamic Performance: High resolution and repeatability optimized for critical analog process control loops and operational balances.

Operating and Mechanical Limits

  • Process Temperature: Extended thermal tolerance range of $-40^\circ\text{C}$ to $230^\circ\text{C}$.
  • Process Pressure: Designed to operate safely under conditions from absolute vacuum up to 60 bar.

Electrical Connectivity and Integration Data

  • Analog Output: Standard 4-20 mA DC current loop for real-time control.
  • Digital Communication: Advanced industrial HART protocols and RS-485 over Modbus digital interface.
  • Network Compatibility: Direct integration into distributed architectures through PLC controllers, DCS systems and SCADA platforms.

Available Materials and Probe Types

To provide maximum adaptability to the different mechanical stresses and chemical compositions of fluids, probes are configured according to each technical requirement:

  • Base Metal Probes: Rods and cables made of industrial-grade SUS304 and SUS316 stainless steel.
  • Insulation and Chemical Coatings: Fully insulated probe options in PTFE / PFA, recommended to prevent electrical short circuits in conductive liquids or to resist attack in highly corrosive environments.
  • Structural Geometries: Variants in rigid rod format (for short lengths and agitated tanks) or flexible cable (for tall silos or deep tanks).

Protection Ratings and Certifications

  • Environmental Sealing: Hermetic housing with IP67 protection against dust and water ingress.
  • Plant Safety: Models and families with approvals and versions suitable for installation in Hazardous Areas with a latent explosion risk.

Typical Plant Applications

  1. Turbulent and Agitated Tanks: Continuous level measurement in reactors and process tanks that experience strong mechanical agitation, waves or surface foam formation.
  2. Phase Separators and Decanters: Accurate interface measurement in hydrocarbon separators, where the separation of layers (light phase / heavy phase) must be controlled precisely.
  3. Tanks with Complex Internal Geometry: Instrumentation in narrow tanks or those with a high density of internal structural obstacles (such as cooling coils or crossing pipes) where non-guided radars lose stability.
  4. Solution and Slurry Preparation: Inventory control in storage tanks for reactive mixtures or slurries with suspended fines, avoiding buildup that would obstruct the instrument.
  5. Wet Material Silos and Hoppers: Robust measurement in powder or granule silos prone to generating dense material clouds or internal condensation.
  6. Clarification and Thickening Circuits: Stable monitoring in settling boxes and recirculation tanks where the product undergoes dynamic, drastic density changes.

There are no products available in this category yet.